Good day !
I have a question regarding the observationShift section, in particular the observationPeriodDates element.
The element contains three options: SetInAdvance, Standard, FixingDate. Everything seems clear with the SetInAdvance value, but there are questions about the other two.
1) Can you explain with an example what "Standard" actually means? Am I correct in my understanding that this is an ordinary observation shift, which may involve the use of a certain number of shift days + take into account rates and their weight from the observation period?
2) Regarding FixingDate, do I understand correctly that this option is used mostly for OIS swaps that have a reset other than 1D, and are based on term-rate 1M, 3M, 6M, etc.? Please explain how this method works too?
Thank you.
Best regards, Maksym
Notes:
MAZA
09/04/23 8:26 am
duplicate.